B型主动脉夹层的EVAR: 经验与教训

作者:  FuWeiguo   日期:2009/4/1 18:05:00

国际循环网版权所有,谢绝任何形式转载,侵犯版权者必予法律追究。

This presentation is to share the experience and lessons in endovascular aortic repair (EVAR) for 550 patients with Stanford type B dissection in terms of preoperative evaluation, operative techniques, ancillary strategies, follow-up, and, in particular, lessons.

EVAR for Stanford Type B Dissections :  Experience & Lessons with 550 cases.

(作者)Fu Weiguo, Dong Zhihui, Wang Yuqi, Guo Daqiao, Xu Xin, Chin Bin, Jiang Junhao, Yang Jue, Shi Zhenyu.
(单位)Zhongshan Hospital, Fudan University, Shanghai

This presentation is to share the experience and lessons in endovascular aortic repair (EVAR) for 550 patients with Stanford type B dissection in terms of preoperative evaluation, operative techniques, ancillary strategies, follow-up, and, in particular, lessons. Firstly, the preoperative evaluation includes imaging protocol, sizing, intervention timing, and risk for ischemia of visceral arteries. Secondly, operative techniques focus on approach selection, judgment of true or false lumen, steps of the procedure and so on. Thirdly, the ancillary strategies involve creation of extra proximal landing zone and supportive reconstruction of visceral arteries, and the indication, technical skills and mid-to-long-term results will be discussed in detail. Fourthly, as an inevitable element of treatment, follow-up is to be described in terms of its protocol and outcome. Finally, we would like to pay emphasis on the lessons we have learnt from these 550 procedures: (1) Ischemic stroke took place in 6 cases(1%) because of air embolism, and thorough saline flush of the stent-graft before introduction is thus considered extremely important. (2) Development of type A dissection was another uncommon complication (11 cases, 2%), in relation to Marfan syndrome, inappropriate endovascular manipulation as well as, potentially, the stent-graft itself.  (3) All 4 cases with Marfan syndrome in this group died within 14 days postoperatively, and 3 were complicated with newly occurred type A dissection and rupture was suspected in 1 case who died suddenly 1 week after discharge. Therefore, EVAR appears to have higher risk for dissection with Marfan syndrome, particularly as an initial treatment. (4) The guide wire could transfer from true lumen into false lumen by accident during catheter or guide wire exchange, leading to disastrous placement of the stent-graft into the false lumen (1 case). (5) Balloon inflation caused migration of the stent-graft in 3 patients at the early stage. Thereafter, it was not used in a routine fashion, and complete thrombosis of the false lumen at the thoracic aorta typically achieved at 3 months, even though slight proximal endoleak could be detected on the completion angiogram in most cases. (6) The stent-graft failed to be deployed in 1 case who was converted to open surgery immediately. So the facilities for transthoracic graft replacement are supposed to be available at the time of EVAR.

版面编辑:杨新象



主动脉夹层EVAR

分享到: 更多


设为首页 | 加入收藏 | 关于我们 | 联系方式 | 招贤纳士
声明:国际循环网( www.icirculation.com)对刊载的所有文章、视频、幻灯、音频等资源拥有全部版权。未经本站许可,不得转载。
京ICP备15014970号-5  互联网药品信息服务资格证书编号(京)-非经营性-2017-0063  京公网安备 11010502033353号  增值电信业务经营许可证:京ICP证150541号
国际循环 版权所有   © 2004-2024 www.icirculation.com All Rights Reserved
公司名称:北京美赞广告有限公司 公司地址:北京市朝阳区朝阳门北大街乙12号天辰大厦1座1409 电话:010-51295530